Synthetic data only. Never enter patient information; nothing is sent or stored. For clinicians. Not FDA cleared.

CPE-002 · synthetic case CPE002-FX-001

Healthy Metabolic Baseline

A 35-year-old with normal glucose, lipids, waist and blood pressure.

Synthetic · no real patientReviewed acceptance scenarioMetabolic engine v1.0.0

Purpose: Confirms the engine stays quiet when nothing meets a criterion.

Inputs the engine received

Patient

Age
35 years
Waist circumference
74 cm
Systolic bp
112 mmHg
Diastolic bp
70 mmHg

Context

Sex for threshold application
female
Fasting confirmed
Yes
Active medication list available
Yes

Laboratory

Fasting plasma glucose
88 mg/dL
Hemoglobin a1c
5.2 %
Triglycerides
90 mg/dL
HDL cholesterol
62 mg/dL

What the engine reports

Detected clinical pattern

No Dysglycemia Criterion Identified

The interpretable test(s) entered do not meet a prediabetes or diabetes criterion. This is not a statement that the patient has no metabolic risk.

  • Glycemic: No Dysglycemia Criterion Identified
  • Validity: Interpretation valid
  • Metabolic syndrome: Metabolic syndrome criteria not met
  • IR-associated pattern: IR-associated pattern: not assessable

Why this pattern was identified

  • No glycemic criterion met. Evaluated: FPG 88 mg/dL; HbA1c 5.2%.

Calculations

TG/HDL-C ratio
1.45

Informational only. No threshold interpretation is enabled; it does not diagnose insulin resistance.

Missing information

  • Fasting insulin (supporting pattern only; fasting and same-collection glucose required).
Evidence and rule trace · 7 rules

GLY-001No Dysglycemia Criterion Identified

Inputs: FPG 88 mg/dL · HbA1c 5.2%

NO_GLYCEMIC_CRITERION_FOR_PREDIABETES_OR_DIABETES_IDENTIFIED

LIPID-001TG to HDL Ratio Informational Calculation

Inputs: TG 90 · HDL-C 62

TG_HDL_RATIO_CALCULATED

MISS-001Insulin Pattern Missing Data

Inputs: fasting insulin not provided

IR_PATTERN_NOT_FULLY_ASSESSABLE_WITH_CURRENT_DATA

IRP-002Hyperinsulinemic Supporting Patternsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

IRP-003Elevated HOMA-IR Supporting Findingsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

IRP-004Convergent IR-Associated Patternsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

TREND-MET-001Composite Metabolic Deterioration Warningsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

Evidence

  • EV-ADA-2026-DIAG · American Diabetes Association Professional Practice Committee for Diabetes. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026. Diabetes Care. 2026;49(Suppl 1):S27-S49.

Physician adjudication required. Clinical decision support only. This output identifies guideline-based glycemic and metabolic findings and risk context. It does not diagnose insulin resistance, select treatment or recommend medication. Physician adjudication is required.

Change the values

The same engine, starting from this case. Change any value and watch the pattern and the rule trace react.

Glycemic testsDrag the sliders to cross a threshold
  • <100
  • 100–125 prediabetes
  • ≥126 diabetes range
  • <5.7
  • 5.7–6.4 prediabetes
  • ≥6.5 diabetes range

75-g protocol

Lipids, body and blood pressure
  • <150
  • 150–499
  • ≥500 priority
  • ≥1000 urgent

Metabolic syndrome components0 of 5

  • ◌ Waist not met
  • ◌ Triglycerides not met
  • ◌ Low HDL-C not met
  • ◌ Blood pressure not met
  • ◌ Fasting glucose not met

● met · ◌ not met · ○ not entered. Three or more meet the criteria; that does not confirm insulin resistance.

Patient and scope
Sex for thresholds
Ketones
Symptoms and safety
Risk context
Liver context
Medications
Outside the standard adult runtime
Fasting insulin (supporting only)Calculation and sandbox

Shown with HOMA-IR when fasting and same-collection are confirmed. It does not classify anything.

Research sandbox (unvalidated)

In production the insulin and HOMA-IR rules are off: no validated threshold profile exists. Here you can supply your own threshold to see how the sandbox rules would behave. The output is labeled a sandbox candidate and is never a diagnosis.

Live result · computed in your browser

Detected clinical pattern

No Dysglycemia Criterion Identified

The interpretable test(s) entered do not meet a prediabetes or diabetes criterion. This is not a statement that the patient has no metabolic risk.

  • Glycemic: No Dysglycemia Criterion Identified
  • Validity: Interpretation valid
  • Metabolic syndrome: Metabolic syndrome criteria not met
  • IR-associated pattern: IR-associated pattern: not assessable

Why this pattern was identified

  • No glycemic criterion met. Evaluated: FPG 88 mg/dL; HbA1c 5.2%.

Calculations

TG/HDL-C ratio
1.45

Informational only. No threshold interpretation is enabled; it does not diagnose insulin resistance.

Missing information

  • Fasting insulin (supporting pattern only; fasting and same-collection glucose required).
Evidence and rule trace · 7 rules

GLY-001No Dysglycemia Criterion Identified

Inputs: FPG 88 mg/dL · HbA1c 5.2%

NO_GLYCEMIC_CRITERION_FOR_PREDIABETES_OR_DIABETES_IDENTIFIED

LIPID-001TG to HDL Ratio Informational Calculation

Inputs: TG 90 · HDL-C 62

TG_HDL_RATIO_CALCULATED

MISS-001Insulin Pattern Missing Data

Inputs: fasting insulin not provided

IR_PATTERN_NOT_FULLY_ASSESSABLE_WITH_CURRENT_DATA

IRP-002Hyperinsulinemic Supporting Patternsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

IRP-003Elevated HOMA-IR Supporting Findingsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

IRP-004Convergent IR-Associated Patternsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

TREND-MET-001Composite Metabolic Deterioration Warningsandbox · off

Sandbox rule — disabled by default. Needs an assay-specific threshold profile and external endocrinology validation.

Evidence

  • EV-ADA-2026-DIAG · American Diabetes Association Professional Practice Committee for Diabetes. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026. Diabetes Care. 2026;49(Suppl 1):S27-S49.

Physician adjudication required. Clinical decision support only. This output identifies guideline-based glycemic and metabolic findings and risk context. It does not diagnose insulin resistance, select treatment or recommend medication. Physician adjudication is required.

More metabolic cases

All metabolic cases

The Clinical Intelligence Layer — transforming fragmented clinical information into structured intelligence for clinician review and action.

Contact Biod